Warranty: | 5 Years |
---|---|
Type: | off Grid Solar Inverter |
Working Model: | MPPT |
Installation: | Wall Mount Installation |
Cooling Method: | Intelligent Cooling Fan |
Size: | 460*304*110mm |
Customization: |
---|
Suppliers with verified business licenses
Parameter
|
|
|
||
Model
|
|
WL-PW5000
|
||
Rated power
|
|
5000W
|
||
Standard voltage
|
|
48VDC
|
||
Installation
|
|
Wall mount installation
|
||
PV Parameter
|
|
|
||
Working model
|
|
MPPT
|
||
Rated PV input voltage
|
|
360VDC
|
||
MPPT tracking voltage range
|
|
120-450VDC
|
||
Max input voltage at lowest temperature
|
|
500V
|
||
Max input power
|
|
6000W
|
||
Number of MPPT tracking paths
|
|
1Path
|
||
Input
|
|
|
||
DC input voltage range
|
|
42-60VDC
|
||
Rated mains power input voltage
|
|
220/230/240VAC
|
||
Grid power input voltage range
|
|
170-280VAC(UPS mode)
120-280VAC(inveter mode) |
||
Grid input frequency range
|
|
40-55Hz(50Hz)
55-65Hz(60Hz) |
||
Output
|
|
|
||
Inverter
|
Output efficiency
|
94%
|
||
|
Output voltage
|
220VAC±2%/230VAC±2%/240VAC±2%(inverter mode)
|
||
|
Output frequency
|
50Hz±0.5 or 60Hz±0.5(inverter mode)
|
||
Grid
|
Output efficiency
|
≥99%
|
||
|
Output voltage
|
Following input
|
||
|
Output frequency
|
Following input
|
||
Battery mode no-load loss
|
|
≤1%(at rated power)
|
||
Grid mode no-load loss
|
|
≤0.5% rated power(the charger of grid power doesn't work)
|
||
Battery
|
|
|
||
Battery type
|
Lead acid battery
|
Equalizing charging 13.8V
Floating charging 13.7V(single battery voltage) |
||
|
Customized battery
|
The parameter can be set according to customers' requirement.Use different types of battery by setting the panel.
|
||
Max mains charging current
|
|
60A
|
||
Max PV charging current
|
|
100A
|
||
Max charging current(Grid+PV)
|
|
100A
|
||
Charging method
|
|
Three-stage(constant current,constant voltage,float charge)
|
||
Protection mode
|
|
|
||
Battery low voltage range
|
|
Battery low voltage protection value+0.5V(single battery voltage)
|
||
Battery voltage protection
|
|
Factory default:10.5V(single battery voltage)
|
||
Battery over voltage alarm
|
|
Equal charging voltage+0.8V(single battery voltage)
|
||
Battery over voltage protection
|
|
Factory default:17V(single battery voltage)
|
||
Battery overvoltage recovery voltage
|
|
Battery over voltage protection value -1V(single battery voltage)
|
||
Overload/short circuit protection
|
|
Automatic protection(battery mode)
Circuit breaker or fuse(Grid mode) |
||
Temperature protection
|
|
≥90 off output
|
||
Performance parameter
|
|
|
||
Parallel capacity
|
|
NO
|
||
Conversion time
|
|
≤4ms
|
||
Cooling method
|
|
Intelligent cooling fan
|
||
Woking temperature
|
|
-10~40
|
||
Storage temperature
|
|
-15~60
|
||
Altitude
|
|
2000m(>2000m altitude need derating)
|
||
Humidity
|
|
0-95%(No condensation)
|
||
Product size
|
|
460*304*110mm
|
||
Package size
|
|
526*384*198mm
|
||
Net weight
|
|
9.5kg
|
||
Gross weight
|
|
10.5kg
|